Use this off grid water system planner to plan water demand, collection, wells, tanks, pressure and pumping energy in a connected off grid water system calculator. Change one input and review how the whole system responds.

Quick answer: An off-grid water system must meet daily water demand, bridge interruptions with usable storage, and deliver adequate pressure and flow. Average rainfall alone cannot establish reliability: water must arrive before it is needed, and tank overflow may discard excess.

Off-Grid Water System Calculator

Two-stream planning: Configure each tank independently and allocate demand and sources between the two streams. The default 55% potable demand allocation is an editable planning assumption, not a health standard. Classification represents intended piping only; drinking water must still be tested and treated. US units can be selected at the top of the form.

Start in Simple mode, then open Advanced for monthly rainfall, detailed demand, source interruptions, pipe losses and reserve scenarios. Calculations use SI internally; volumes in results show litres and US gallons. Hidden Advanced settings remain active. Review them before relying on a result.

1 · Household water demand

Garden, animals, cleaning, etc. not already counted per person.
Detailed household consumption (optional override)

If enabled, calculated demand uses these household-wide activities instead of people × daily allowance; extra daily use is still added.

2 · Water supplies

Used only when no monthly rainfall is entered; NOT a reliable drought forecast.
Combined runoff and filtration/first-flush losses.
Based on sustainable tested yield and allowable daily extraction, not pump nameplate flow.
Do not count the same water under two sources.
For planning, enters on the first day of every model month.
These allocations represent separate plumbing/storage streams, not water-quality certification. Verify treatment and safe physical separation.
Monthly rain and seasonal reliability
When blank, annual rain is apportioned by month length, then placed on synthetic wet days, which can conceal dry seasons. Enter a full local monthly series for a meaningful seasonal assessment.
Rain is concentrated into evenly spaced wet days. This is a stress-test assumption, not a weather forecast.
Independent source-transfer paths and outages

Each source has a dedicated pump budget, with no shared flow priority. Enter flow verified against a manufacturer curve at the stated total dynamic head (including drawdown, lift, friction, fittings and treatment losses). The planner does not predict pump flow from head. One pump serving multiple sources is outside this model; do not enter it as multiple independent pumps. Only water physically transferred to storage is credited. Rainwater is assumed to enter by gravity unless marked pump-dependent. Sustainable yield and pump transfer limits are separate constraints.

Well transfer path

Other supply transfer path

Rain collection transfer path

Tests no roof collection for consecutive days starting on model day 1.

3 · Independent tank storage

Designated potable tank
Nonpotable tank
Water suitability and demand separation

This tool does not assess water potability. Keep drinking-water storage, treatment and plumbing physically separated where required; each tank has a separate daily quantity balance; water never transfers automatically between streams. Do not use pooled results to justify cross-connections.

4 · Water delivery and pumping

Pump: vertical rise; gravity: tank water surface above outlet.
Advanced hydraulic inputs
For turbulent water in full, pressurized pipe. Low-Reynolds-number results are flagged as unsuitable; viscosity assumed at 20°C.
For pumped household distribution only; independent of source-transfer pumping. In pump-fed mode the default is 170 L/day; set to actual delivered volume.

Your Water System Results and Recommendations

Calculator unavailable until JavaScript runs. The planning guide below remains available.

Input snapshot and modelling assumptions

Source contributions and reliability

Tank balance sampled every five days: baseline year

365-day approximation: monthly rainfall arrives on evenly spaced synthetic wet days; monthly deliveries occur on day one. Dry-spell testing estimates sensitivity but does not reproduce real storm sequences.

Monthly water-balance breakdown
Month Supply (L) Demand (L) End tank (L) Unmet (L)

Operational feasibility and delivery assessment

System bottlenecks and improvement actions

How to Use the Off Grid Water System Planner

Supply from a roof, well, spring or hauled deliveries enters storage. Storage smooths out differences between water arrival and demand. Gravity or a pump then supplies fixtures at the required flow and residual pressure. Proper system design also requires site-specific water treatment, source protection, valves, overflow, venting, backflow controls and electrical safeguards.

How to Calculate Water Demand

Multiply household occupants by an editable per-person daily allowance, then add independently supplied uses such as irrigation and livestock. When measured data is available, use the detailed activity override to avoid relying on a single average. The model reports daily, monthly and annual demand; do not treat presets as universal consumption standards.

Planning Rainwater, Wells and Backup Water Sources

Rainwater captured in litres equals roof area in square metres × rainfall depth in millimetres × total collection factor. Well contribution must be based on sustainable available yield, not a short-duration pump test. Hauled supply is represented as discrete monthly deliveries rather than smooth continuous inflow. Rainwater and well water may need separate treatment and distribution; this tool does not establish potability.

How to Size Water Storage

No-refill usable requirement equals daily demand × autonomy days. Nominal tank sizing must also allow for unusable water below the outlet and the selected protected reserve. A full tank’s theoretical autonomy is different from autonomy at today’s actual fill level. The daily balance limits stored water to physical capacity, counts overflow, protects reserve and identifies unmet demand.

Gravity-Fed and Pumped Water Delivery

Gravity static pressure depends on water-surface elevation above an outlet. Moving water loses energy in pipe friction and fittings. Pumped delivery requires a duty point combining vertical rise, pressure requirement and hydraulic losses; manufacturers’ pump curves must be checked before selection. Estimated pumping energy is based on water volume, total dynamic head and a user-entered combined efficiency.

Planning for Dry Seasons and Emergencies

Compare your normal plan with a rainfall reduction, well reduction, increased consumption and a temporary pump interruption. An average annual surplus does not guarantee daily reliability. Where rainfall is uncertain, use measured multi-year monthly or daily rainfall records and independently assess drought conditions.

Worked Off-Grid Water System Example

A two-person household using 75 L per person per day plus 20 L additional daily demand needs 170 L/day. With 14 days of no refilling, that is 2,380 L of usable water. With a protected 300 L reserve and 5% inaccessible tank volume, nominal capacity required from a full tank is (2,380 + 300) ÷ 0.95 = 2,821.05 L. This is a no-refill planning estimate, not a commercial tank recommendation. Each tank must independently meet its allocated demand and reserve; sufficient combined capacity alone is not enough.

Common Water System Planning Mistakes

Avoid confusing a pump’s maximum flow with flow at its operating head; treating total tank volume as usable; counting the same well water twice; using annual rainfall as proof of dry-season supply; or assuming a water source is drinking-water safe simply because sufficient volume exists.

Frequently Asked Questions

How much water does an off-grid home need per day?

It depends on occupants, appliances, sanitation and outdoor use. Enter measured consumption when possible and allow for peak days rather than assuming one universal number.

How large should an off-grid water tank be?

Choose a desired interruption period, multiply it by daily demand, then add reserve and allowance for unusable tank volume. Validate this against actual seasonal arrivals and delivery reliability.

Can rainwater supply an entire off-grid home?

Potentially, where roof area, rainfall distribution, storage and water quality management support it. Annual collection exceeding annual demand alone is not proof.

How do I combine well water and rainwater?

Estimate each source independently, avoid double-counting and simulate when each reaches storage. Keep potable and nonpotable plumbing appropriately separated and protected against cross-connections.

How much emergency water should I store?

Set a site-specific reserve based on expected interruption duration, household needs and reliable backup supply. The tool does not prescribe health-related emergency minimums.

Can gravity-fed water supply fixtures?

Only if minimum water-surface elevation provides adequate pressure after flow losses. Evaluate each fixture’s manufacturer requirements.

How much electricity will a water pump use?

Estimated kWh equals ρg × pumped volume (m³) × total dynamic head (m) ÷ (combined efficiency × 3,600,000). Actual energy also depends on operating point and controls.

What happens if my well runs dry?

Without usable alternative inflow, stored water declines as demand continues. The outage scenario excludes the selected failed source or all pump-dependent inflow for the specified days. Household pressure-pump outages can additionally prevent fixture service even if water remains in storage.

How can I plan for seasonal rainfall changes?

Enter twelve monthly rainfall values rather than relying on an annual average; for rigorous sizing, test daily multi-year rainfall and prolonged dry intervals.

Can solar power operate the water system?

Yes, if the pump’s start/run electrical characteristics, required daily energy, controller, solar array and storage are properly matched. This calculator estimates pumping energy only.

Safety and model limitations. This planner estimates quantities, head and energy; it does not certify potable water, pump curves, pressure ratings or compliance. Test water quality and plan appropriate filtration/disinfection with qualified professionals. Address rain and well contamination, backflow prevention, potable/nonpotable cross-connections, dry-run protection, overflow, structural tank loads, freezing and local plumbing/electrical regulations. Pipe loss is estimated for full water pipes with Hazen–Williams; actual installations need manufacturer data and site verification.

Technical references

CDC: rainwater collection and health · Hydraulic Institute: system curves

Next Step Links

Related Tools

Explore the specialist calculators for more detailed component sizing. Compare water demand, collection, storage and delivery requirements before choosing components.


Water tool directory: choose your next topic

Start with this connected planner, then use specialist tools for the part of your system you need to investigate.

Planning, storage and troubleshooting

Rainwater and wells

Pumps, pipes and pressure

Filtration and treatment

Water use and energy

Water-System Equipment to Compare

These product examples can help you turn a preliminary water plan into an equipment shortlist. Confirm all sizes, power needs, fittings, pressure limits, and potable-water ratings against your own design.

Augason Farms 55-Gallon Water Storage Barrel

A large-capacity option for emergency and household water reserves. Check placement, filling access, and food-contact suitability before selecting.

Click for the latest price.

SEAFLO 33-Series 12V Diaphragm Water Pump

A self-priming DC pump for pressurized delivery where the system flow, head, and electrical supply match its specifications.

Click for the latest price.

iSpring WSP50 Spin-Down Sediment Pre-Filter

A flushable first-stage sediment screen that can help protect downstream equipment. It does not disinfect or make unsafe water potable.

Click for the latest price.

Winters 0–100 PSI Liquid-Filled Pressure Gauge

A pressure-monitoring instrument useful for checking a suitable water line. Verify fitting size, materials, and pressure range.

Click for the latest price.

As an Amazon Associate I earn from qualifying purchases. Product availability and specifications may change. These links are sponsored affiliate links. No product alone ensures drinking-water safety: test the source and use treatment appropriate to its contaminants. Consult qualified professionals for installation, plumbing, and electrical safety.