Water Tank Size & Volume Calculator
Calculate water tank capacity from internal dimensions, find how much water remains at a measured fill level, or work backward from a desired capacity to a required tank dimension. Compare vertical cylinders, horizontal cylinders with flat ends, and rectangular tanks in US or metric units.
Conceptual AI-generated illustration, not an installation or fabrication drawing.
How Do I Calculate Water Tank Capacity in Litres or Gallons?
For a rectangular tank, multiply internal length × width × full height. A tank measuring 2 m × 1 m × 1.5 m holds 3,000 litres (about 792.5 US gallons) before allowances for headspace or unusable water. For a full cylinder, use π × radius² × height or length. Choose the correct orientation below to calculate a partially filled tank.
Looking for how big a tank your household needs? Start with the Water Usage & Storage Calculator to estimate demand and backup days, then return here to compare physical tank dimensions. Cisterns fit this calculator only when their internal geometry matches a supported shape.
Measure the tank you actually have
- Choose the shape and orientation. Use inside dimensions, not external measurements or nominal pipe sizes.
- Enter the current vertical water depth measured from the lowest internal bottom. If measuring air space from the top, subtract it from the total internal height first.
- Calculate to see full volume, current water and empty space. Simple mode assumes no protected reserve or unusable bottom zone.
- Use Advanced mode for water below the outlet, a separate reserve, a target fill level or a desired-capacity sizing comparison.
Calculate tank size and water volume
Enable JavaScript to calculate. If this notice remains, your page may be blocking inline scripts. The formulas and worked examples below remain readable.
US inputs use feet and US liquid gallons. Metric inputs use metres and litres. Unit changes convert values without changing the physical tank.
Results appear after calculation. All initial values are editable examples.
Your tank volume
Ideal internal volume up to the geometric top; manufacturer working capacity may be lower.
Volume corresponding to the measured water depth.
Fraction of capacity occupied by water, which differs from depth percentage in a horizontal tank.
Current water minus the water below the draw-off level and any protected reserve.
Simple mode uses the geometric top; Advanced mode uses your target depth.
Full geometric capacity minus current water; this is not permission to fill to the brim.
Where the current water is allocated
The protected reserve is additional to water below the draw-off level. If current storage cannot provide the entire reserve, the shortfall is reported instead of inventing water.
Dimension for the desired full capacity
Depth-to-volume reference
Fractions refer to water depth, not to volume. A horizontal cylinder has a nonlinear relationship between depth and volume.
| Depth | Water stored | Volume fill |
|---|
Geometry only. Results do not approve tank construction, supports, pressure/vacuum limits, foundations, lifting, water quality or drinking-water use. Verify usable capacity with manufacturer specifications or a calibrated fill chart.
Tank capacity, stored water and usable water
Full geometric capacity is the ideal volume within the entered inside dimensions. Current water depends on measured depth and tank orientation. Available water subtracts only water actually present below the selected draw-off level, followed by the protected reserve above it. It does not subtract an empty bottom zone from storage a second time.
Manufacturer ratings may include headspace, overflow elevations, domed bases or nominal model names. A correct ideal-geometry calculation can therefore differ from a real tank’s labelled capacity. For an existing irregular tank, use the manufacturer’s chart or an appropriately measured calibration. Do not enter a tank or climb an unsecured structure to take dimensions.
Worked examples you can reproduce
Vertical cylinder
A flat-bottom vertical cylinder with 6 ft internal diameter and 8 ft internal height holds approximately 1,692.054 US gal. At 3 ft water depth, it contains 634.520 US gal, or 37.5% by volume. Load the vertical shape example in US units to reproduce these results.
Horizontal cylinder
A level, flat-ended horizontal cylinder with 2 m inside diameter and 3 m length has 9,424.778 L full geometric capacity. At 0.5 m depth, it contains 1,842.555 L, or about 19.55% of capacity. At half its diameter, it contains exactly half its full geometric volume. Select horizontal, load its example, and choose metric units.
Rectangular tank and reverse sizing
A rectangular tank 2 m long × 1 m wide × 1.5 m high holds 3,000 L. At 0.75 m water depth, it stores 1,500 L. With a 0.1 m unusable bottom depth and a separate 100 L reserve, water available is 1,200 L. Raising the water to 1.2 m requires 900 L more. For a separate 5,000 L full-capacity design using the same width and full height, required length is 3.333 m. Select rectangular, load its example, and enable both Advanced mode and desired-capacity sizing.
Formulas and calculation order
Use consistent length units. For a vertical cylinder of radius r, water volume at depth h is V(h) = πr²h. For a rectangular tank of length L and width W, V(h) = LWh. Full capacity uses the tank’s full internal height instead of h.
For a level horizontal cylinder of radius r and straight length L, V(h) = L[r² arccos((r − h)/r) − (r − h)√(2rh − h²)], with angles in radians and 0 ≤ h ≤ 2r. Full volume is πr²L. The implementation uses an equivalent circular-segment expression, symmetry above half depth and a small-angle series near empty to avoid subtracting nearly equal values.
Let C = full geometric capacity, S = V(current depth), B = V(unusable bottom depth), and R = protected reserve. Current bottom water = min(S, B); current water above the bottom zone = max(0, S − B); reserve held = min(R, max(0, S − B)); available = max(0, S − B − R). The table reports geometric water volume before these exclusions.
Volume change to target = V(target depth) − S: positive means add, negative means remove, and zero means already at target. No flow or refill time is assumed. Reverse sizing uses the desired full volume divided by the full cross-sectional area: required height for a vertical cylinder, required length for a horizontal cylinder, or required length for a rectangle using its entered full width and height.
Assumptions and limits
Use a level tank of one ideal shape with flat ends or bottom. The model excludes domed and dished heads, tapered or conical sections, bladders, wall thickness, internal components, sediment displacement and tank deformation. It does not infer pressure-tank drawdown or the usable fraction of a pressure vessel.
Active dimensions must be 0.01–100 m (equivalent feet in US mode). Water, outlet and target depths must lie from zero to the selected tank’s internal height or diameter. Reserve is limited to the full geometric capacity above the selected unusable bottom zone. Desired capacity is 0.001–1,000,000,000 L. If the reverse-sized dimension lies outside 0.01–100 m, the tool reports that it is outside this calculator’s supported range rather than presenting it as a supported design.
Software bounds are not recommendations for practical tank sizes. US gallons differ from Imperial gallons. Exact conversions: 1 ft = 0.3048 m; 1 US gal = 3.785411784 L; 1 m³ = 1,000 L. Display values are rounded; calculations retain the entered precision. Very small positive volumes use scientific notation.
Practical tank-planning guidance
- Check whether a quoted diameter or length is internal or external. Walls, end shapes and fittings can materially change actual capacity.
- Use horizontal cylinder length only between flat ends. A cylinder with dished or domed heads requires their separate geometry or a manufacturer fill chart.
- Measure water depth vertically from the same bottom reference. Sloping ground does not make a tilted tank fit the level-tank model.
- Allow actual operating headspace and use the real outlet/overflow limits. Geometric empty space is not a certified safe filling allowance.
- Use the resulting volume in a separate demand or refill calculation. This tool does not establish household autonomy, rain reliability or well yield.
- Have the chosen tank and support arrangement checked against equipment specifications, site conditions and applicable requirements.
Frequently asked questions
Can I use external tank dimensions?
Use internal dimensions. External measurements include wall thickness and may include feet, fittings or domed ends. The manufacturer’s capacity or calibration chart is preferable when inside geometry is uncertain.
Why is a horizontal tank not 25% full at one-quarter depth?
The water first occupies a narrow curved segment near the bottom, then a wider region near the centre. At one-quarter diameter depth, the volume is about 19.55% of full capacity. Depth and volume percentages match at empty, half depth and full.
Does this include rounded or domed ends?
No. The horizontal model includes only a straight circular cylinder with flat ends. Real tank heads can add volume with a different depth relationship; use a suitable manufacturer chart instead.
How do I convert a top-down dip measurement?
For these supported shapes, water depth equals total internal vertical height minus the measured empty space above the water. For a horizontal cylinder, that total height is its inside diameter. Use the same top and bottom reference points.
Does the reserve include water below the outlet?
No. The selected bottom-water depth defines water excluded from normal draw-off. The protected reserve is an additional volume above that zone. When there is too little water to hold the entire reserve, the shortfall is shown and available water is zero.
Can I choose the tank size from the capacity I need?
Advanced mode can solve one dimension for a desired full geometric capacity. It keeps the entered diameter fixed for cylinders, or width and full height fixed for a rectangle. It does not select a product or account for headspace, wall design, supports or operating reserve.
Why does my labelled tank capacity differ?
Real tanks may have rounded shoulders, tapered walls, dished heads, internal equipment or rated headspace. Dimensions may also be external or nominal. Use a manufacturer’s operating-capacity figure when that is the value needed for your plan.
Does this calculate refill time or pressure?
No. It calculates geometry and volume only. Refill time needs measured net flow and use timing; pressure needs water head or pump-system information.
Sources and related water planning
Wolfram MathWorld: circular-segment geometry gives the segment-area relationship used for horizontal fill. The Open University: volumes of uniform cross-sections explains the area-times-length basis for cylinders and rectangular forms.
Plan water demand and storage duration using the available-water volume from this calculator.
Educational planning estimate. Volume alone does not establish water quality, potable use, construction suitability, safe loads or code compliance. Confirm real tank geometry and operating limits before relying on a result.
Recommended Water Tank Measurement & Monitoring Tools
Measure dimensions and real water movement to refine your tank-volume estimates. Level sensors give alerts or readings only within their supported tank types and installation limits.
Klein Tools 9225 Tape Measure
Measures accessible tank height, width, diameter and available installation space. For irregular tanks, use the manufacturer’s rated internal capacity.
Click for the latest price.RESTMO Hose Water Flow Meter
Tracks hose-delivered flow and total fill volume on compatible fittings, useful when estimating water added to a tank. Not intended for permanent potable-water plumbing.
Click for the latest price.YoLink Water Level Sensor Starter Kit
Hub and float-switch sensor for high/low level alerts at an installed switching point. It does not continuously measure tank volume; confirm tank and mounting compatibility.
Click for the latest price.Mopeka Pro Check Universal Level Sensor
Ultrasonic level monitoring for certain compatible tanks, with specific material and capacity limits. Check the exact model’s water-tank compatibility before ordering.
Click for the latest price.As an Amazon Associate, we earn from qualifying purchases. Product suitability, supported tanks and availability vary.
Recommended Pressure Tank Sizing & Maintenance Tools
The right measuring tools help you verify water pressure, check pressure tank air precharge, and measure installation dimensions before selecting or maintaining a pressure tank.
Rain Bird P2A Water Pressure Test Gauge
A 0–200 PSI water pressure gauge with a standard garden-hose connection. Useful for checking system pressure at compatible faucets when evaluating pressure tank operation.
Click for the latest price.JACO ElitePro Digital Pressure Gauge
A digital air pressure gauge with a 5–100 PSI measuring range. Can help check pressure tank air precharge through a compatible Schrader valve after water pressure has been safely relieved.
Click for the latest price.Topeak JoeBlow Sport III Floor Pump
A manual floor pump with a pressure gauge and Schrader-compatible pump head. Useful for adjusting air precharge on compatible pressure tanks according to manufacturer instructions.
Click for the latest price.iGaging Absolute Origin 6-Inch Digital Caliper
A stainless steel digital caliper for measuring fitting diameters, valve components, and small installation clearances. Displays measurements in inches and millimeters. Confirm nominal pipe and thread sizes against manufacturer specifications.
Click for the latest price.As an Amazon Associate, we earn from qualifying purchases. Product suitability and availability may vary.
