Off Grid Living Tools · Solar Power & Energy

Battery Chemistry Comparison Calculator

LiFePO₄ vs AGM vs flooded vs gel. Compare the battery capacity you can actually use, the upfront price, and the modeled long-term cost of off-grid storage.

Simple & Advanced ModesFour battery chemistriesEditable real-world assumptions

This free Battery Chemistry Comparison Calculator helps you evaluate LiFePO₄ and deep-cycle lead-acid batteries using a common daily energy requirement. Instead of comparing amp-hours alone, estimate the usable capacity, batteries required, purchase cost, and lifetime energy of each battery type. Advanced Mode lets you replace illustrative defaults with actual manufacturer specifications and supplier prices.

Quick answer: Is LiFePO₄ better than lead-acid for off-grid solar? LiFePO₄ commonly offers greater usable depth of discharge and higher cycle-life ratings, while lead-acid often costs less upfront. The best value depends on actual product prices, operating temperatures, discharge rates, daily energy use, and the tested cycle life at the chosen depth of discharge. This tool compares scenarios; it does not certify equipment or predict exact battery lifespan.

Compare your battery options

Enter what you need to power. Compare equivalent delivered energy, not just advertised amp-hours.

Energy the loads actually receive per day
Days without charging
Example: 12.8 V × 200 Ah = 2.56 kWh
0.8 = about 292 equivalent cycles/year
Long-term budget horizon

Advanced assumptions: All fields are editable. Cycle life must correspond to the selected DoD. Set the same delivered-energy demand for every chemistry; use current local quotes rather than treating defaults as market prices.

LiFePO₄

Scenario assumption
At the entered DoD
Stored energy delivered
Illustrative, replace with quotes
Assumed age limit

AGM deep-cycle

Scenario assumption
At the entered DoD
Stored energy delivered
Illustrative, replace with quotes
Assumed age limit

Flooded deep-cycle

Scenario assumption
At the entered DoD
Stored energy delivered
Illustrative, replace with quotes
Assumed age limit

Gel deep-cycle

Scenario assumption
At the entered DoD
Stored energy delivered
Illustrative, replace with quotes
Assumed age limit

Comparison results

Lowest upfront bank cost—
Lowest modeled 10-year module cost—
Lowest modeled lifetime $/kWh—
Battery chemistry comparison results
Battery typeUsable / moduleModulesBank capacity deliveredUpfront bank costModeled useful yearsHorizon module costCost / lifetime delivered kWh

Upfront cost comparison

Formula notes: usable module kWh = nominal kWh × DoD × delivery efficiency. Module count is rounded up to cover delivered daily demand × autonomy days. Equivalent cycles/year = cycles/day × 365. Modeled lifetime years = minimum(cycles / equivalent cycles/year, calendar life), when cycles/day is above zero; otherwise calendar life. Horizon module cost = initial bank cost × comparison years / modeled lifetime years, an annualized fractional-replacement approximation; actual purchases occur in discrete replacement events. Lifetime delivered kWh = usable bank kWh × nominal rated cycles, limited by cycle use within calendar life. Actual performance varies by chemistry, manufacturer, load and temperature.

How the battery comparison works

1. Compare usable energy

Nominal capacity is not what a load receives. Depth of discharge and delivery efficiency both reduce usable kWh. Lead-acid capacity ratings are particularly sensitive to load current and temperature.

2. Size each battery bank fairly

All chemistries are sized for the same daily delivered kWh and autonomy target. Module counts are rounded upward; the cost comparison does not assume equal module quantities provide equal runtime.

3. Compare cycle life on equivalent terms

A cycle-life figure at 50% DoD is not equivalent to one tested at 80% DoD. Advanced Mode allows matching actual cycle ratings to chosen usable DoD assumptions.

4. Separate upfront cost from lifetime cost

Purchase price alone may favor lead-acid, but replacements can change long-term economics. Calendar aging and low-cycle seasonal use can reverse that conclusion. Actual installed costs and discounts are excluded.

Safety and real-world limitations

Not an equipment approval. Charging lithium batteries below freezing can be prohibited without approved heating/protection; flooded lead-acid installations can require ventilation and regular service. Confirm BMS, fusing, temperature ratings, charger profile, discharge current, fire separation and local electrical rules for the actual product. Never connect batteries of different chemistries or specifications unless the manufacturer explicitly permits the configuration.

For battery bank sizing and wiring, use the dedicated tools linked below. For battery comparisons, focus on equivalent tested specifications and verified supplier quotes, not generic chemistry marketing figures.

Battery chemistry comparison FAQs

Is LiFePO₄ always cheaper than AGM?

No. LiFePO₄ often supplies more usable energy and more cycles, but purchase price, duty cycle, calendar aging, delivery costs and verified specifications can change the economic result.

What does depth of discharge mean?

Depth of discharge (DoD) is the percentage of rated stored energy used in a cycle. A 5 kWh nominal battery at 80% DoD makes 4 kWh available before delivery-efficiency adjustments.

Why is cycle life not a universal chemistry number?

Cycle life changes with the tested DoD, temperatures, charging patterns, discharge rates and end-of-life capacity threshold. Compare manufacturer data using equivalent tests.

How is cost per delivered lifetime kWh calculated?

This planning metric divides assumed bank purchase cost by modeled delivered throughput over its useful life. The tool includes fractional final replacement cost in its horizon scenario but does not account for financing or salvage.

What is the difference between AGM and flooded batteries?

Both are lead-acid. AGM is sealed valve-regulated equipment; flooded deep-cycle batteries require approved ventilation, inspection and potentially electrolyte maintenance. Product-specific charging limits differ.

Should I use lithium NMC for an off-grid house?

NMC can be suitable in engineered products, but thermal management, enclosure certification and battery-management specifications matter. This initial tool compares LiFePO₄ and three deep-cycle lead-acid types rather than assuming all lithium products behave alike.

Can lithium batteries charge below freezing?

Many LiFePO₄ batteries prohibit charging below 0°C unless they have a suitable heated battery or manufacturer-approved protection. Confirm the exact cell and BMS specifications.

Does this calculator account for high discharge current?

No. Lead-acid rated capacity can vary substantially with discharge current (Peukert behavior). Large loads require manufacturer discharge curves and cable/fuse verification.

Does this tool include installation and charger costs?

The main bank-price scenario includes battery modules only. Add quotes for wiring, enclosures, charging equipment, labor, monitoring and maintenance before purchasing.

What does the 10-year cost actually mean?

It is a scenario budget for replacements and service using assumed cycle-life and calendar-life limits. It is not a guaranteed warranty value or a net-present-value model.

Which batteries need maintenance and ventilation?

Flooded lead-acid needs proper service access and ventilation. All battery installations need compliant siting and protection; even sealed types require manufacturer-approved installation.

How do I compare batteries for an RV or cabin?

Start with required delivered kWh per day, acceptable DoD, actual purchase quotes, room temperature and weight limits. Use the results to shortlist compatible products, then verify discharge-current and charging requirements.

Next Step Links

Battery Chemistry Comparison Calculator is a preliminary planning model. For purchase, installation or safety decisions, use product-specific manufacturer documentation and qualified electrical advice.

Helpful equipment

Battery Equipment to Compare

Check exact manufacturer specifications, charger settings, temperature limits and safety instructions. Product examples do not establish battery-system compatibility.

LiTime LiFePO4 Deep-Cycle Battery

Compare lithium iron phosphate capacity, cycle-life claims and charging requirements.

Click for the latest price.

Renogy 500A Battery Monitor

Measure battery use and state of charge with a correctly installed shunt monitor.

Click for the latest price.

Victron SmartSolar MPPT 100/50 Charge Controller

Compare the charging profiles and voltage limits required by your battery chemistry.

Click for the latest price.

Renogy 3000W Pure Sine Wave Inverter

Compare inverter efficiency and input voltage to assess useful AC energy delivery.

Click for the latest price.

This section contains affiliate links. We may earn a commission.

Battery chemistry reference

Chemistry affects usable energy, service life, charging limits and safety requirements; no single battery type is best for every system. See the U.S. Department of Energy’s solar energy storage overview. Verify the specific battery and BMS documentation before selecting charge or discharge settings.

Scroll to Top