Off Grid Living Tools · Maintenance & System Health · Task 050

Battery Health & Capacity Log

Record battery-bank readings, compare documented capacity measurements with rated capacity, and preserve a useful maintenance history—without confusing charge level with battery health.

Open battery health log ↓
WHY BATTERY HEALTH MATTERS

A battery can be charged without being healthy

Your battery bank can indicate 100% state of charge while storing less energy than it did when new. Capacity changes with age, use, temperature, chemistry and measurement conditions. A dated record of capacity tests, BMS observations, temperature and cycle counts is more useful than treating a single voltage or state-of-charge reading as proof of health.

Track change over time

Keep dated observations for a named bank, using the same measurement method whenever practical.

Separate facts from estimates

Distinguish a qualified full-capacity measurement from BMS readings and partial-use estimates.

Plan informed service

Preserve observations and maintenance notes for your technician, installer or warranty provider.

START HERE

How to use the Battery Health & Capacity Log

  1. Name your bank. Use the same identifier as your Equipment Inventory.
  2. Enter the rating. Use the battery-bank nominal voltage and rated amp-hour capacity—not a guess based on current charge.
  3. Identify the evidence. Choose whether the reading comes from a controlled full-capacity test, BMS, monitor or estimate.
  4. Add observations. Enter measured Ah if available, plus SOC, temperature and cycle count. Empty optional fields stay unknown.
  5. Use Advanced when supported. Record delivered watt-hours and test duration from reliable instrumentation without conducting unsafe tests.
  6. Calculate, save and back up. Review the interpretation, save the dated record, and download a verified JSON backup.

Important: Never perform a deep discharge, disconnect a battery, open a battery enclosure or bypass its protection system merely to use this log. Follow the manufacturer’s testing procedure and qualified service guidance.

Battery capacity tracking workspace

The highlighted button is the active mode. Advanced mode reveals additional energy and discharge readings below the standard battery fields.

Use a stable name for comparable records.
Use the bank’s actual series/parallel rating.
Do not invent a value from SOC or voltage.
Enter observations, then calculate.

Inspection history and backups

0 saved observations

Records stay in this browser only; they do not sync across devices or automatically transfer to other maintenance tools. Download JSON backups regularly.

Restore a Task 050 JSON backup

Restoring replaces this browser’s current Task 050 records after validating the backup. Export the current records first.

UNDERSTAND YOUR RESULTS

State of charge versus state of health

State of charge (SOC) describes how much charge a monitor estimates is present now. State of health (SOH) concerns how the battery’s usable performance compares with a reference condition. This tool only displays a nominal-capacity comparison when you select a qualified controlled full test and provide measured amp-hours. It cannot verify that the test was performed correctly.

Illustrative capacity comparison

A 200 Ah battery measured at 164 Ah during an appropriate full test gives 164 ÷ 200 × 100 = 82% of nominal amp-hour capacity. This does not automatically establish warranty eligibility, safety or replacement timing. Test rate, temperature, cutoff voltage, chemistry and manufacturer protocol matter.

Why watt-hours and amp-hours differ

Amp-hours measure charge moved; watt-hours measure energy. Multiplying nominal voltage by nominal Ah gives a nominal reference, not a guarantee of deliverable energy in a particular test. A monitor-reported energy value is preserved separately. We do not convert a partial discharge to a claimed full-capacity health score.

Keep records comparable

Use the same bank identifier, rated capacity basis, instrumentation and manufacturer-approved test conditions. Note calibration, starting state, battery temperature, discharge rate, cutoff rules and whether the battery bank changed between observations.

PRACTICAL GUIDANCE

What battery health trends can mean

Reported SOC suddenly jumps

Review monitor synchronization, battery settings and BMS communication. An SOC jump does not prove a sudden capacity change.

Lower delivered energy in cold weather

Temperature affects available capacity and charging limits. Compare equivalent conditions, not just raw numbers.

Capacity falls across comparable tests

Document the trend and review manufacturer criteria with a qualified professional before planning replacement.

Heat, swelling, odor or damage

Do not touch or test a suspect battery. Follow the manufacturer’s emergency guidance from a safe location and seek qualified help.

Safety: Battery systems can deliver dangerous fault currents and, for some chemistries or failures, fire or hazardous gases. Never defeat a BMS, handle damaged cells, short terminals, open packs, or force a full discharge to improve a result in this log.

Pair this record with the Maintenance Schedule Generator and Preventive Maintenance Checklist. Keep the manufacturer’s current instructions as the authority for service decisions.

Useful battery monitoring and maintenance accessories

Optional equipment for observation and recordkeeping. Verify your battery chemistry, system voltage and installation compatibility before purchasing. Product links may earn a commission at no extra cost to you.

Victron SmartShunt battery monitor

Records current flow and supports SOC monitoring when correctly installed and configured. It is not a direct capacity certification.

Click for the latest price

Battery monitor with shunt

A compatible monitor can provide usage trends for supported banks. Compare measurement range and wiring requirements.

Click for the latest price

Infrared surface thermometer

For non-contact observations at safely accessible surfaces; emissivity and viewing conditions affect readings.

Click for the latest price

Weather-resistant document organizer

Store battery manuals, warranties, service notes and printed inspection history together.

Click for the latest price

What’s next?

Use your saved capacity observations to identify which equipment requires attention, then plan inspections in the Maintenance Schedule Generator. Task 051, Water Pump Maintenance Tracker, is next in the approved roadmap and should only be linked here after it is published.

Frequently asked questions

Can I calculate battery health from voltage alone?

No. Voltage changes with charge state, temperature, load and chemistry. It is not an adequate standalone measure of remaining battery capacity.

Does 100% SOC mean my battery is still at 100% health?

No. SOC is a current charge estimate. An aged battery can be fully charged yet have less usable capacity than its nominal rating.

Why does the tracker sometimes show no health percentage?

It intentionally withholds a numeric capacity comparison unless you enter measured amp-hours from a qualified full-capacity test. Informal or partial readings are logged without being promoted to verified health.

Is 80% capacity an automatic replacement rule?

No. Some specifications use that threshold as a cycle-life reference, but serviceability depends on manufacturer criteria, required loads, safety and warranty conditions.

Can I use this with lithium and lead-acid batteries?

Yes for recordkeeping. Testing procedures and interpretation differ by chemistry; select the correct type and follow its specific manufacturer instructions.

Where is my history stored?

Only in this browser’s local storage. JSON exports preserve verified backups for restore. CSV is for review or spreadsheet analysis and cannot be restored.

Sources and limitations

This tool is a personal record and arithmetic comparison, not a diagnostic instrument, laboratory capacity test, safety certification, battery warranty assessment or engineering approval. The user supplies every measurement and is responsible for recording its provenance accurately.

Scroll to Top