Well Yield & Water Recovery Calculator

Turn measured well-test readings into a clearer water-supply picture. Calculate average pumping yield, drawdown, specific capacity and observed recovery in US or metric units, then explore how much water the wellbore itself stores.

Capped domestic well and water-level meter near a timber cabin in wooded hills

Conceptual AI-generated illustration, not an installation drawing.

Well depth is not well yield. A short test can draw heavily on stored borehole water. Neither recovery speed nor a gallons-per-minute result establishes a sustainable pumping rate, drinking-water safety or a safe pump setting.

How to use your measurements

  1. Use an existing well test or ask a qualified well contractor to measure discharge, time and water levels. Example values below are editable, not measurements of your well.
  2. Measure every depth from one fixed reference point. Enter the nonpumping level and the level at shutdown.
  3. Add a recovery reading only if all pumping stopped during that interval. Enter the actual inside diameter for storage estimates.
  4. Use Advanced mode for well geometry and a storage-only peak-demand check. Replace the example operating limit with a professionally selected value.

Read your well test

Enable JavaScript to calculate. If this notice remains, inline scripts may be blocked. The guidance and worked example below remain available.

US means US liquid gallons, feet and inches. Changing units converts entered values. Times stay in minutes.

Pumping observations

Measured water discharged during the whole pumping test; not tank nameplate capacity.

Minutes of pumping associated with that discharge volume. Rate is a test average.

Before pumping, after adequate rest. All depths use the same fixed measuring point.

Water level immediately before stopping the pump; larger depth means lower water.

Actual water-filled inside diameter across the level change; nominal casing size can differ.

Recovery after pump shutdown

Measure after pumping has stopped, using the same measuring point.

Minutes since pump shutdown. No other pumping or discharge-line backflow assumed.

Results appear after calculation.

What well yield and recovery actually tell you

Measured pumping yield is water discharged per unit time during a particular test. Some discharged water may have been stored in the borehole before pumping began. Recovery is the rise in water level after pumping stops. With a uniform bore, that rise gives a geometric estimate of water returning to borehole storage over the observed interval.

Recovery usually changes with time and hydraulic head. Fast initial recovery does not mean the same rate continues all day. Sustainable abstraction depends on aquifer properties, seasonal water levels, recharge, nearby pumping, environmental impacts and local requirements. Those cannot be inferred from total well depth or this endpoint calculator.

Worked example: a 6-inch domestic well

A test discharges 300 US gal in 60 minutes. Static depth is 40 ft and shutdown depth is 80 ft. Average pumping yield is 5 US gal/min, drawdown is 40 ft, and specific-capacity screening estimate is 0.125 (US gal/min)/ft. This screening calculation uses the average rate; use a constant-rate test for meaningful comparisons.

After 30 minutes without pumping, water is at 50 ft. The 30 ft rise represents 75% recovery, about 44.06 US gal regained in a uniform 6-inch bore, and 1.469 US gal/min average net inflow during that interval. It does not establish a sustainable yield of 1.469 US gal/min or predict when the remaining 25% will recover.

Advanced example: total depth 200 ft, intake 150 ft and selected water cover 10 ft give a 140 ft level limit. Gross storage above that limit is 146.88 US gal at static level and 88.13 US gal at shutdown. A hypothetical 8 US gal/min demand for 20 minutes needs 160 US gal; the static storage-only comparison is short by 13.12 US gal. Inflow is deliberately excluded, and this comparison is not an approved pump run time.

Method, assumptions and input limits

Let V be test discharge, t pumping minutes, S static depth, P shutdown depth, R recovered depth, u recovery minutes, and A = πd²/4 the bore area. Average discharge Q = V/t; drawdown s = P − S; specific capacity = Q/s when s > 0. Recovered height = P − R; recovery percent = 100(P − R)/s. Gross regained volume = A(P − R), using consistent length units; average net recovery inflow = regained volume/u. At zero drawdown, recovery percent and specific capacity are undefined, rather than infinite.

Advanced level limit C = intake depth − selected water cover. Gross static storage above the limit = A max(0, C − S); gross shutdown storage = A max(0, C − P). Peak demand = assumed rate × minutes. The storage-only difference uses static storage and assumes zero inflow. Even a storage surplus cannot establish safe submergence, actual delivered flow or reliable supply.

Assumes a vertical, uniform circular water-filled bore over each modeled interval, negligible equipment displacement, no simultaneous pumping during recovery and no discharge backflow. Screen/open-hole diameter changes, cascading water, leakage, fractures and measurement error can invalidate the storage-to-inflow interpretation. It does not estimate transmissivity, aquifer storage coefficient, recharge or groundwater sustainability.

Bounds, expressed in US units: volume 0–10 million US gal; pumping/recovery duration 0.01–10,080 min; depths 0–1,500 ft; inside diameter 0.5–120 in; peak rate 0–10,000 US gal/min; peak duration 0.01–1,440 min. Advanced well depth, intake and water cover must be positive. Metric bounds represent the same quantities. These are software limits, not suitable operating ranges. Conversions: 1 US gal = 3.785411784 L; 1 ft = 0.3048 m; 1 in = 25.4 mm.

Plan the next step carefully

  • Have a qualified well contractor choose the pumping-test procedure, rate, discharge route, monitoring interval and stopping limits. Do not deliberately run a domestic pump dry to obtain a yield figure.
  • Record baseline water level after rest, repeated discharge rates and water levels during pumping, and timed recovery readings after shutdown. Use one measuring reference and prevent backflow. Discharge must not recycle into the well or cause damage.
  • Endpoint readings cannot show whether water level stabilized. Compare tests only with similar pumping rates, durations and seasonal conditions; retain the full record for professional interpretation.
  • Ask about low-water cutoff, minimum submergence, motor cooling, sand protection and water-quality sampling. An arbitrary percentage reduction from a measured rate is not a safe-rate prescription.
  • If peak demand exceeds available supply, spread out high-use activities, conserve water or discuss intermediate storage with a professional. A pressure tank’s usable drawdown differs from its nameplate volume.

Frequently asked questions

Can well depth predict gallons per minute?

No. Depth and diameter describe geometry; yield depends on the water-bearing formation and test conditions. Deeper drilling may add storage without adding reliable inflow, and may change water quality.

Is recovery inflow the same as sustainable well yield?

No. This tool reports an average net inflow over one observed recovery interval. It is affected by hydraulic head and test conditions, and should not be multiplied by 1,440 to claim a reliable daily supply.

How long should a well yield test last?

There is no universal duration suitable for every domestic well or permitting purpose. A professional should set the protocol for the geology, intended use and local rules. Public-supply permitting procedures are not automatically domestic DIY instructions.

Why is specific capacity unavailable at zero drawdown?

The formula divides discharge by drawdown. At zero drawdown that ratio is undefined; very small drawdown also makes it sensitive to measurement error. Neither proves unlimited well capacity.

Can the calculator tell me when recovery reaches 100%?

No. A single interval cannot describe a nonlinear recovery curve. Continue observing under a suitable test protocol; this tool reports only the recorded change.

What if the recovery level is above the initial static level?

The simple recovery interpretation no longer fits. Check the measuring reference, rainfall, nearby pumping, backflow and baseline conditions. The calculator rejects that combination rather than labeling it more than 100% recovery.

Does a high measured yield mean the water is safe to drink?

No. Quantity testing does not establish water quality. Use appropriate laboratory sampling, treatment assessment and local health guidance.

Sources & related planning

Method references: USGS: specific-capacity tests in low-yielding bedrock wells explains the effect of wellbore storage and limits of yield extrapolation. Penn State Extension: using low-yielding wells discusses peak demand, borehole storage and intermediate storage. New York DEC pumping-test procedures provides professional measurement and recovery-recording context for permit applications, rather than a universal home-well test standard.

Educational planning only. Have the well record, equipment limits, water quality and proposed operating plan reviewed by a qualified well professional. Results do not establish sustainability, potability, regulatory compliance or engineering approval.


Recommended Well Testing & Monitoring Tools

Measuring water flow and pressure helps you understand how your well system performs. These tools support preliminary troubleshooting and water monitoring, but they cannot independently determine a well’s sustainable yield or aquifer recovery rate.

Water Flow Measurement

RESTMO Water Flow Meter

Measures flow rate and total water volume through compatible garden-hose connections. Useful for preliminary timed discharge measurements when testing a well system. Confirm that your discharge flow and fittings are compatible with the meter’s specifications.

Click for the latest price.
Water Pressure Measurement

Rain Bird P2A Water Pressure Test Gauge

A 0–200 PSI water pressure gauge designed for compatible hose-thread connections. Helps check pressure at accessible system outlets when investigating pump operation, water delivery or pressure fluctuations.

Click for the latest price.
Water Quality Screening

Watersafe Well Water Test Kit

Provides preliminary screening for selected water-quality indicators. Useful when reviewing well-water treatment requirements. It does not measure well yield, recovery rate or sustainable pumping capacity. Laboratory testing is needed for a comprehensive drinking-water safety assessment.

Click for the latest price.
Installation Measurement

Klein Tools 9225 Tape Measure

A 25-foot measuring tape for checking accessible surface-level distances, equipment clearances, pipe runs and installation dimensions. Not suitable for measuring deep well-water levels. Professional well-level measuring equipment may be required for drawdown and recovery testing.

Click for the latest price.
Important well-testing safety information: Accurate well-yield and recovery testing requires measurements of discharge flow and water-level drawdown over time. Do not lower household measuring tools, electrical equipment or improvised devices into a well casing. Avoid running a pump dry. Consult a qualified well professional when determining sustainable yield or performing extended pumping tests.

As an Amazon Associate, we earn from qualifying purchases. Product availability and suitability may vary.

Recommended next steps

Use reliable observations and the assumptions shown by each tool. Planning estimates do not establish equipment suitability or drinking-water safety.

Well Testing & Measurement Accessories

Use these as examples of measuring equipment only. The calculator cannot determine whether a pumping test is safe or sufficient, and a qualified well professional should specify the actual procedure.

Solinst 101 P7 Water Level Meter — 200 ft

Professional water-level meter for static, pumping and recovery depth readings. Confirm probe access and measurement range.

Click for the latest price.

RAINPOINT Hose-End Water Flow Meter

Tracks discharged water volume and flow through compatible hose-thread outlets. Not a substitute for an approved well-pumping test setup.

Click for the latest price.

United Solutions 5-Gallon Graduated Measuring Bucket

Graduated container for controlled volume checks at suitable discharge points. Verify markings and calibrate before relying on readings.

Click for the latest price.

Dretec Digital Stopwatch Timer

Handheld timing aid for recording pumping and recovery intervals alongside written measurements.

Click for the latest price.

Do not remove well caps, lower probes, run pumps dry, or alter equipment without proper authorization and professional safety controls. Prevent well contamination and discharge backflow.

This section contains affiliate links. We may earn a commission.

Scroll to Top