Off Grid Living Tools · Maintenance & System Health · Task 050
Battery Health & Capacity Log
Record battery-bank readings, compare documented capacity measurements with rated capacity, and preserve a useful maintenance history—without confusing charge level with battery health.
Open battery health log ↓A battery can be charged without being healthy
Your battery bank can indicate 100% state of charge while storing less energy than it did when new. Capacity changes with age, use, temperature, chemistry and measurement conditions. A dated record of capacity tests, BMS observations, temperature and cycle counts is more useful than treating a single voltage or state-of-charge reading as proof of health.
Track change over time
Keep dated observations for a named bank, using the same measurement method whenever practical.
Separate facts from estimates
Distinguish a qualified full-capacity measurement from BMS readings and partial-use estimates.
Plan informed service
Preserve observations and maintenance notes for your technician, installer or warranty provider.
How to use the Battery Health & Capacity Log
- Name your bank. Use the same identifier as your Equipment Inventory.
- Enter the rating. Use the battery-bank nominal voltage and rated amp-hour capacity—not a guess based on current charge.
- Identify the evidence. Choose whether the reading comes from a controlled full-capacity test, BMS, monitor or estimate.
- Add observations. Enter measured Ah if available, plus SOC, temperature and cycle count. Empty optional fields stay unknown.
- Use Advanced when supported. Record delivered watt-hours and test duration from reliable instrumentation without conducting unsafe tests.
- Calculate, save and back up. Review the interpretation, save the dated record, and download a verified JSON backup.
Important: Never perform a deep discharge, disconnect a battery, open a battery enclosure or bypass its protection system merely to use this log. Follow the manufacturer’s testing procedure and qualified service guidance.
Battery capacity tracking workspace
The highlighted button is the active mode. Advanced mode reveals additional energy and discharge readings below the standard battery fields.
Capacity interpretation
Inspection history and backups
0 saved observations
Records stay in this browser only; they do not sync across devices or automatically transfer to other maintenance tools. Download JSON backups regularly.
Restore a Task 050 JSON backup
Restoring replaces this browser’s current Task 050 records after validating the backup. Export the current records first.
State of charge versus state of health
State of charge (SOC) describes how much charge a monitor estimates is present now. State of health (SOH) concerns how the battery’s usable performance compares with a reference condition. This tool only displays a nominal-capacity comparison when you select a qualified controlled full test and provide measured amp-hours. It cannot verify that the test was performed correctly.
A 200 Ah battery measured at 164 Ah during an appropriate full test gives 164 ÷ 200 × 100 = 82% of nominal amp-hour capacity. This does not automatically establish warranty eligibility, safety or replacement timing. Test rate, temperature, cutoff voltage, chemistry and manufacturer protocol matter.
Why watt-hours and amp-hours differ
Amp-hours measure charge moved; watt-hours measure energy. Multiplying nominal voltage by nominal Ah gives a nominal reference, not a guarantee of deliverable energy in a particular test. A monitor-reported energy value is preserved separately. We do not convert a partial discharge to a claimed full-capacity health score.
Keep records comparable
Use the same bank identifier, rated capacity basis, instrumentation and manufacturer-approved test conditions. Note calibration, starting state, battery temperature, discharge rate, cutoff rules and whether the battery bank changed between observations.
What battery health trends can mean
Reported SOC suddenly jumps
Review monitor synchronization, battery settings and BMS communication. An SOC jump does not prove a sudden capacity change.
Lower delivered energy in cold weather
Temperature affects available capacity and charging limits. Compare equivalent conditions, not just raw numbers.
Capacity falls across comparable tests
Document the trend and review manufacturer criteria with a qualified professional before planning replacement.
Heat, swelling, odor or damage
Do not touch or test a suspect battery. Follow the manufacturer’s emergency guidance from a safe location and seek qualified help.
Safety: Battery systems can deliver dangerous fault currents and, for some chemistries or failures, fire or hazardous gases. Never defeat a BMS, handle damaged cells, short terminals, open packs, or force a full discharge to improve a result in this log.
Pair this record with the Maintenance Schedule Generator and Preventive Maintenance Checklist. Keep the manufacturer’s current instructions as the authority for service decisions.
Useful battery monitoring and maintenance accessories
Optional equipment for observation and recordkeeping. Verify your battery chemistry, system voltage and installation compatibility before purchasing. Product links may earn a commission at no extra cost to you.
Victron SmartShunt battery monitor
Records current flow and supports SOC monitoring when correctly installed and configured. It is not a direct capacity certification.
Click for the latest priceBattery monitor with shunt
A compatible monitor can provide usage trends for supported banks. Compare measurement range and wiring requirements.
Click for the latest priceInfrared surface thermometer
For non-contact observations at safely accessible surfaces; emissivity and viewing conditions affect readings.
Click for the latest priceWeather-resistant document organizer
Store battery manuals, warranties, service notes and printed inspection history together.
Click for the latest priceRecommended tools



What’s next?
Use your saved capacity observations to identify which equipment requires attention, then plan inspections in the Maintenance Schedule Generator. Task 051, Water Pump Maintenance Tracker, is next in the approved roadmap and should only be linked here after it is published.
Frequently asked questions
Can I calculate battery health from voltage alone?
No. Voltage changes with charge state, temperature, load and chemistry. It is not an adequate standalone measure of remaining battery capacity.
Does 100% SOC mean my battery is still at 100% health?
No. SOC is a current charge estimate. An aged battery can be fully charged yet have less usable capacity than its nominal rating.
Why does the tracker sometimes show no health percentage?
It intentionally withholds a numeric capacity comparison unless you enter measured amp-hours from a qualified full-capacity test. Informal or partial readings are logged without being promoted to verified health.
Is 80% capacity an automatic replacement rule?
No. Some specifications use that threshold as a cycle-life reference, but serviceability depends on manufacturer criteria, required loads, safety and warranty conditions.
Can I use this with lithium and lead-acid batteries?
Yes for recordkeeping. Testing procedures and interpretation differ by chemistry; select the correct type and follow its specific manufacturer instructions.
Where is my history stored?
Only in this browser’s local storage. JSON exports preserve verified backups for restore. CSV is for review or spreadsheet analysis and cannot be restored.
Sources and limitations
- NREL/Sandia — PV and Storage O&M Best Practices
- Victron — Battery monitor synchronization and troubleshooting
- U.S. Department of Energy — PV system performance and maintenance
This tool is a personal record and arithmetic comparison, not a diagnostic instrument, laboratory capacity test, safety certification, battery warranty assessment or engineering approval. The user supplies every measurement and is responsible for recording its provenance accurately.