Calculate your hot-water plan

Start with Simple mode. Advanced mode exposes the loss, efficiency, draw-pattern and off-grid assumptions. All assumptions remain active when you return to Simple mode.

Your household and temperatures

Read the results

Daily demand is water already mixed to your chosen delivery temperature. Because a hotter tank can mix with cold water, the stored-hot draw is usually smaller. The tank estimate covers your busiest-hour draw with an editable usable fraction and sizing margin. It deliberately gives no credit for recovery while drawing, but it is still not a guarantee: stratification, inlet turbulence, plumbing layout and product controls can reduce delivery.

Compare a storage heater’s certified first-hour rating with demand at compatible temperatures. For tankless heaters, check flow at the actual winter temperature rise and any required minimum flow. Neither tank litres nor a daily kWh figure proves that a heater can serve simultaneous showers.

How the calculator works

Water is approximated as 1 kg/L with a heat capacity of 4.186 kJ/(kg·°C). All internal calculations use litres, Celsius, kW and kWh. US conversions use 3.785411784 L/US gal and °C = (°F − 32) × 5/9. Temperature differences convert by 9/5 without adding 32.

  • Daily mixed volume = people × mixed use per person.
  • Stored-hot fraction = (delivery − inlet) ÷ (storage − inlet).
  • Storage estimate = peak mixed volume × hot fraction ÷ usable fraction × (1 + margin). Round up to 5 L.
  • Useful draw heat = mixed litres × 4.186 × delivery rise ÷ 3600.
  • Daily thermal load = useful draw heat × (1 + distribution-loss fraction) + standby heat loss.
  • Daily electric or gas input = thermal load ÷ conversion efficiency. These are thermal efficiencies, not overall UEF ratings.
  • Full-tank heating hours = tank litres × 4.186 × storage rise ÷ 3600 ÷ (heater input kW × efficiency).
  • Instantaneous thermal kW = mixed L/min × 4.186 × delivery rise ÷ 60; electric input divides by electric efficiency.
  • Solar thermal contribution = daily thermal load × assumed solar coverage. Remaining load divides by backup efficiency. Solar thermal does not mean PV.
  • PV kW = daily electric kWh ÷ (peak sun hours × PV delivered-energy factor). Battery nominal kWh = daily electric kWh ÷ inverter efficiency ÷ usable battery fraction.

Independent example: heating 100 L from 15°C to 50°C takes 14,651 kJ = 4.0697 kWh of heat. A 2 kW electric heater at 98% needs 2.0764 hours and 4.1528 kWh, before heat loss. With 15% distribution loss and 0.8 kWh/day standby, that daily draw needs 5.5920 kWh/day of electricity.

Limits: steady conditions, one shared delivery temperature, fixed losses and efficiencies, no heat-pump COP, no solar collector simulation, no live weather, no recovery during tank sizing and no plumbing disinfection prediction. Full-tank heating is an ideal lower estimate because ambient losses and control cycles are excluded. Enter separate scenarios for uses at different temperatures. Zero warm-water use still incurs the entered standby loss.

Hot-water safety before installation

Do not use this calculator to decide that water is safe to drink, that a tank is disinfected, or that an installation is safe. Water heating is not a complete treatment plan for untreated off-grid supplies.

Prevent burns and scalds

Storage temperature and safe tap delivery are different decisions. CDC advises thermostatic mixing when household storage exceeds 120°F (about 49°C). Children, older adults and people with reduced sensation need particular protection. Have suitable certified mixing and anti-scald devices selected, fitted, tested and maintained professionally; a thermostat display alone does not protect taps.

Manage Legionella and stagnation

CDC household advice discusses 130–140°F (about 54–60°C) storage alongside burn prevention and individual risk assessment. Canadian public-health advice uses 60°C storage with mixed delivery limited to 49°C. These are jurisdiction-specific approaches, not universal instructions. The default 60°C is a modeling assumption. Ask a qualified professional about local requirements, vulnerable occupants, dead legs, sediment, intermittent cabin occupancy and commissioning after stagnation. A nominal setpoint or brief heating cycle does not prove the entire system controls Legionella. Follow manufacturer maintenance instructions; do not improvise thermal disinfection.

Electrical and pressure protection

Use a qualified electrician to check supply voltage, earthing/bonding, required RCD/GFCI protection, isolators, wiring and overcurrent protection under local rules. Do not select a circuit, breaker, cable or inverter solely from the displayed current. Isolate and verify power off before service. Fill and purge the tank before energizing as the manufacturer directs. Use a listed pressure-rated potable-water heater; provide correctly installed temperature-and-pressure relief discharge and required expansion control. Never plug or cap a relief outlet.

Gas, combustion and solar systems

Gas installation requires a qualified gas professional, correct fuel type and pressure, approved venting, combustion air and manufacturer clearances. Never use an outdoor-only portable heater indoors or in an enclosed cabin. Install and maintain CO alarms according to local rules and alarm instructions. If you smell gas, leave without operating electrical switches and contact the gas emergency service from a safe location. If a CO alarm sounds or CO poisoning is suspected, get outside and call emergency services.

Solar thermal needs suitable freeze and overheat protection, pressure relief and potable-water separation from heat-transfer fluids. A 100% average solar assumption is not a safe backup design. Do not reduce cloudy-day backup capacity using average solar coverage.

Practical off-grid planning

Measure flow with a timed container and record shower duration. Use the coldest expected inlet temperature for power and recovery planning. Insulate suitable tanks and pipes without obstructing vents, controls or relief devices. Check whether a smaller efficient showerhead can reduce both water demand and energy. Do not trade microbial or scald protection for energy savings.

Resistance water heating can dominate a small battery system. Compare gas availability, manufacturer-rated heat-pump equipment, daytime PV heating and properly designed solar thermal. Heat pumps need a separate performance model for ambient temperature and recovery. Keep winter sun, multiple cloudy days and other electrical loads in your whole-system design.

Frequently asked questions

How do I use a water heater size calculator?

Estimate mixed warm-water use and your busiest hour, then enter winter inlet, delivery and storage temperatures. Check the storage estimate against a manufacturer’s certified delivery rating and your actual fixture pattern.

Is tank size the same as first-hour rating?

No. Tank size is physical storage. First-hour rating includes delivery and reheating under defined test conditions. This tool does not calculate a certified first-hour rating.

How much energy heats 100 litres by 35°C?

About 4.07 kWh of heat reaches the water. At 98% electric conversion efficiency that is about 4.15 kWh of electricity before distribution and standby losses.

Can I lower storage temperature to save energy?

Do not choose a safe operating temperature from an energy result. Lower storage can increase microbial risks; hotter water increases scald risk. Use local public-health advice, the manufacturer and a qualified installer, with suitable thermostatic mixing.

Can solar heat supply all my hot water?

A high average solar fraction does not guarantee supply on a cold or cloudy day. Solar thermal needs a site-specific collector, storage and backup design. PV-powered resistance heating also needs enough instantaneous electrical power.

Does this cover heat pumps or tankless selection?

Electric results model resistance heating, not a heat-pump COP. The flow result is an ideal instantaneous load estimate, not a product selection. Use a manufacturer performance curve at your winter temperature rise.

Water-heating equipment and maintenance accessories to compare

Compare these model-specific examples against the calculator’s storage, heat-up, flow and energy estimates. These are not installation approvals. Have a qualified installer verify safe sizing, local electrical and gas codes, combustion venting, pressure relief, scald protection and potable-water suitability. The outdoor propane heater is never suitable for enclosed or indoor use.

This section contains affiliate links. We may earn a commission.

Bosch Tronic 3000 T ES2.5 Electric Mini-Tank Water Heater

Small point-of-use electric storage option. Compare storage volume, recovery and circuit needs.

Click for the latest price.

EcoSmart ECO 11 Electric Tankless Water Heater

High-input electric tankless example; compare winter temperature-rise flow and dedicated 240 V supply.

Click for the latest price.

Eccotemp L5 Portable Outdoor Propane Tankless Water Heater

Outdoor-only portable propane example. Never operate indoors or in an enclosed space.

Click for the latest price.

Camco Water Heater Tank Rinser (11691)

Maintenance accessory for compatible tank heaters; follow safe shutdown and cooling instructions.

Click for the latest price.

Next step tools

Connect the hot-water estimate to your complete power system.

Related water tools

Check the water supply that supports your hot-water system.

Sources and review

Research reviewed 2 November 2026. Planning model, not a certified engineering design.

Scroll to Top