Pressure Tank Sizing Calculator

Find the right well pressure tank size for a conventional fixed-speed pump. Estimate usable drawdown, nominal tank capacity, pressure-switch settings and pump cycling—with Simple and Advanced modes.

Blue well pressure tank with gauge, pressure switch and plumbing in a clean off-grid water utility room

Jump to Calculator

Quick answer: For a fixed-speed well pump, a preliminary minimum drawdown is pump flow rate × desired minimum run time. The pressure tank’s advertised nominal capacity is not its usable drawdown. For example, a 10 US gal/min pump with a 1-minute minimum run time needs approximately 10 US gallons of drawdown—often a much larger nominal pressure tank, depending on cut-in, cut-out and precharge pressures.

Well Pressure Tank Size Calculator

Assumes an intact diaphragm/bladder pressure tank, a conventional fixed-speed pump and a pressure switch. Use the pump’s actual delivered flow through its operating pressure range.

Calculator loading. If controls remain unavailable, JavaScript may be blocked.

Flow the pump actually delivers near the operating pressures, not its advertised maximum.

Use the pump maker’s specified minimum run time. One minute is only an example.

Examples only; verify the actual switch gauge readings.

0 is the conservative no-demand pump-fill calculation. Advanced mode adds cycle scenarios.

What Size Pressure Tank Do I Need?

A well pressure tank size calculator helps you match a diaphragm or bladder tank to a pump’s output and minimum continuous run time. A pump that refills a very small pressure tank rapidly can cycle too often. For a conventional pressure-switch system, a larger usable drawdown generally provides longer refill time, subject to demand and the pump’s actual operating curve.

A 44-gallon pressure tank does not provide 44 gallons of usable drawdown. Part of the vessel remains compressed air, and usable water depends on cut-in, cut-out and air precharge.

Pressure Tank Sizing Worked Example

Consider a 10 US gal/min fixed-speed pump, a 40/60 psi pressure switch and 38 psi empty-tank air precharge. A one-minute minimum run-time target requires 10 gallons of drawdown. Using standard atmosphere (14.696 psi), the idealized drawdown factor is approximately 0.258, giving a preliminary minimum nominal volume of approximately 38.8 US gallons. Select a suitable commercially available pressure tank only after comparing its manufacturer-rated drawdown at your settings, pressure rating and pump requirements.

For example, an existing nominal 44-gallon tank under the same idealized assumptions provides about 11.35 gallons of drawdown. At zero water use, refill time is approximately 1.14 minutes for a constant 10 gal/min pump. Actual pump flow typically varies with pressure, so the real time can differ.

How the Drawdown Formula Works

First, required usable drawdown equals pump flow rate multiplied by the desired minimum pump run time. Next, the idealized air volume is estimated using Boyle’s law, assuming isothermal gas compression and an intact bladder or diaphragm. The calculation uses absolute pressures, not gauge pressures, for each pressure ratio.

For air precharge at or below cut-in, the approximate fraction of nominal tank volume delivered between cut-out and cut-in is:

f = P₀(abs) × [1 / Pcut-in(abs) − 1 / Pcut-out(abs)]

Then minimum tank volume = required drawdown / f. The calculated factor can differ from manufacturer tables because membrane displacement, actual vessel geometry, hysteresis, temperature and testing conditions matter. Never buy solely on this theoretical value.

Well Pump Short Cycling and Advanced Checks

Short cycling can result from insufficient usable drawdown, incorrect air precharge, a waterlogged tank, incorrect pressure-switch settings, leaks or other faults. This calculator estimates tank-side volume, not a pump’s actual on/off control response. If your modeled water demand equals or exceeds pump flow, it cannot compute a refill-to-cut-out time: the pump cannot catch up under the assumed constant rates.

Variable-speed/VFD and constant-pressure installations need manufacturer-specific sizing and controls. A fixed-speed pressure-switch tank model may substantially oversize or incorrectly characterize such systems.

Important Installation and Safety Limitations

  • Check precharge only with pump power isolated and the tank water pressure fully relieved, following the manufacturer’s safety procedures. A common Amtrol guidance value is 2 psi below switch cut-in, but the actual equipment manual governs.
  • Confirm the tank’s pressure rating, relief valve, switch rating, installation orientation, potable-water suitability and local requirements. Do not use this calculator as pressure-vessel certification.
  • Do not assume a pump’s label maximum flow equals its flow at 40–60 psi; verify the pump curve across the pressure band and piping losses.
  • Tank sizing does not demonstrate groundwater availability. Check well recovery and sustainable yield separately.
  • Damaged bladders, waterlogged vessels and fluctuating supply pressure invalidate ideal-gas estimates.

Pressure Tank FAQ

What size pressure tank do I need for a 10 GPM well pump?

At a one-minute minimum run time, preliminary required usable drawdown is 10 US gallons. At 40/60 psi with 38 psi precharge, the idealized calculation suggests about 38.8 US gallons nominal capacity. Confirm manufacturer-rated drawdown, pump curve and minimum run time before purchasing.

How do I calculate pressure tank drawdown?

Multiply nominal tank volume by the estimated usable drawdown factor or use the manufacturer’s tested drawdown table for the tank model and pressure settings. Drawdown is water discharged between pump cut-out and cut-in, not total tank size.

Should pressure tank precharge be 2 psi below cut-in?

For many conventional bladder well tanks, yes: for example 38 psi air precharge for a 40 psi cut-in switch, measured with the tank empty and water pressure relieved. Verify the manufacturer’s instructions because other systems use different requirements.

Will a larger tank stop well pump short cycling?

An undersized tank may contribute, and more drawdown usually lengthens cycles. However, loss of air charge, leaks, control faults, pump problems and damaged bladders also cause rapid cycling; correct diagnosis is necessary.

Can I use this for constant-pressure or VFD pumps?

No. Constant-pressure and variable-speed systems often have different tank sizing requirements. Consult the pump/controller manufacturer’s guidance.

Related Tools and Next Steps

Next Step Links

Sources and Methodology

Sizing basis: Pentair WellMate pressure-tank sizing guide (drawdown = pump flow × minimum run time; manufacturer factors/tables for final selection); Amtrol well tank support (precharge guidance); Amtrol pressure vessel specifications (equipment-specific pressure ratings). Last model review: November 2026. This independent calculator is not affiliated with these manufacturers.

Recommended next steps

Use reliable observations and the assumptions shown by each tool. Planning estimates do not establish equipment suitability or drinking-water safety.

Pressure Tank Testing & Equipment

These are relevant equipment examples, not selections produced by the calculator. Verify rated drawdown, pressure settings, certifications and installation compatibility before ordering.

Amtrol Well-X-Trol WX-202 Pressure Tank

20-gallon nominal pressure tank. Check its manufacturer-rated drawdown at your actual switch pressures before choosing a size.

Click for the latest price.

Square D Pumptrol 9013FSG2J21 Pressure Switch

30/50 psi switch for compatible pump controls. Confirm electrical rating, connection and settings before replacement.

Click for the latest price.

Parts2O TC2104 Well Pump Pressure Gauge

0–100 psi gauge with 1/4-inch connection for checking operating pressure. Verify fitting and potable-water suitability.

Click for the latest price.

MEASUREMAN Water Pressure Test Gauge

Hose-thread test gauge with maximum-pressure pointer for observing system pressure at a suitable test point.

Click for the latest price.

Pressure vessels and pump controls can be hazardous. Isolate power and depressurize the system before servicing; use a qualified installer where required.